Circulation Arteries
LEED Goals
Code Analysis
0.2in/occupant Stairs, 0.15in/occupant Other- Sprinkled
1024 Assembly
1024.6.1-2 At least0.005in of additional stair width for each occupant shall be provided for each 0.10in of riser above 7in
1024.7 Travel Distances- Exits and Aisles shall be so located that the travel distance to an exit door shall not be greater than 250ft in sprinkled buildings.
1024.9.1 Minimum aisle width-
1. Forty-eight inches for aisle stairs having seating on each side
2. Thirty-six inches for aisle stairs having seating only one side
4. forty-two inches for level or ramped aisles having seating both sides
5. thirty-six inches for level or ramp aisles having seating only one side
1108.2.2.1 Accessible Wheel Chair spaces (seating)- (6+4)= 10 total
Below is my FULL Code Analysis for my building.
okc_velodrome_code_analysis.docx |
Theaters- 1 space per 4 seats (380)
Retail- 1 per 200 sq ft up to 12,000 sq ft (60) 65,514 total sq ft
1 per 225 sq ft 12,001 to 48,000 (143)
1 per 250 sq ft over 48,001 sq ft (70)
Total Spaces: 653
Handicap: 13
Regular: 640